To create eco-friendly environment, we are now very conscious about our environment. We have a bio-chemical ETP (Effluent Treatment Plant) having 3 cubic meters per day in order to ensure that the waste water has been treated according to BSR/DOE requirement to confirm sustainable green environment. Facility have highly equipped in-house Lab with competent lab technicians to perform onsite test & making sure that the quality of our treated water are in correct parameter. We have highly trained Environment and Chemical responsible person Jobayer Rahman who have distinguished academic credentials of B.Sc. in Textile Engineering (Wet Processing) to discharge their effective governance in the area of Environment & Chemical related requirements even upcoming environmental challenges.
Power Consumption-2017 |
||||
Sl No |
Month | Electricity From Generator (kWh) | Purchased Electricity (kWh) | Total Energy Consumption (kwh) |
1 |
Jan | 2937 | 58804 | 61741 |
2 |
Feb | 1756 | 37575 |
39331 |
3 |
Mar | 6063 | 53736 |
59799 |
4 |
Apr | 9221 | 60996 |
70217 |
5 |
May | 6519 | 64081 |
70600 |
6 | Jun | 3676 | 55262 |
58938 |
7 |
Jul | 2566 | 57266 |
59832 |
8 |
Aug | 4289 | 43703 |
47992 |
9 |
Sep | 2414 | 42425 |
44839 |
10 |
Oct | 7266 | 77052 |
84318 |
11 |
Nov | 1799 | 55805 |
57604 |
12 |
Dec | 1663 | 47902 |
49565 |
Total | 50169 | 654607 |
704776 |
Result of the Ambient Air (Indoor) Quality Test |
|||||||
Sl No |
Test Parameter | Units | Method of Analysis | Result | DoE Standard for Ambient Air | IFC/World Bank Standard |
Remarks |
1 |
SPM | µg/m3 | Gravimetric | 98.72 | 200 | NYS |
Acceptable |
2 |
O3 | µg/m3 | Gas Monitor/ Transmitter | 103 | 157 | 160 |
Acceptable |
3 |
VOC | L/MLH | Air Quality Monitor | 211 | NYS | NYS |
– |
4 |
CO2 | ppm | Air Quality Monitor | 87 | NYS | NYS | – |
5 |
SO2 | µg/m3 | West-Gaeke | 63.3 | 120 | 125 |
Acceptable |
6 |
NOx | µg/m3 | Jacob and Hochheiser | 21.3 | 100 | 200 |
Acceptable |
7 | CO | µg/m3 | CO Meter | 521 | 10000 | NYS |
Acceptable |
Total GHG Emission 2017 |
||
Name of the Month |
Tones |
Remark |
January |
36.504 | |
February |
22.684 |
|
March |
37.349 |
|
April |
44.747 |
|
May |
43.299 |
|
June |
35.541 | |
July |
35.62 | |
August |
29.967 |
|
September |
26.547 |
|
October |
49.685 |
|
November |
33.168 |
|
December |
29.16 |
|
Grand Total (Tones) |
424.271 |
|
Per Month (Tones) |
35.356 |
Total Ground Water Withdrawal Summary – 2017 |
||
Name of the Month |
Total Water Consumption (m3) |
Remarks |
January |
672.45 |
|
February |
611.31 |
|
March |
669.06 |
|
April |
738.82 |
|
May |
806.47 |
|
June |
661.3 |
|
July |
809 |
|
August |
705.26 |
|
September |
602.82 |
|
October |
729.099 |
|
November |
1004.896 |
|
December |
944.538 |
|
Grand Total (m3) |
8955.023 |
|
Per Month (m3) |
746.252 |
|
Per Day (m3) |
24.88 |
|
Per Hour (m3) |
1 |
Total Treated water By Bio-Chemical ETP – 2017 |
|||
Name of the Month |
ETP Inlet Water (m3) | ETP Outlet Water (m3) |
Remark |
January |
25.85 |
25.84 |
|
February |
38.39 |
34.58 |
|
March |
40.84 |
28.95 |
|
April |
48.88 |
28.18 |
|
May |
57.047 |
33.249 |
|
June |
43.57 |
22.96 |
|
July |
51 |
36.45 |
|
August |
42.21 |
27.34 |
|
September |
33.938 |
10.673 |
|
October |
55.839 |
52.032 |
|
November |
57.106 |
39.027 |
|
December |
57.127 |
33.357 |
|
Grand Total (m3) |
551.797 |
372.638 |
|
Per Month (m3) |
45.983 |
31.053 |
|
Per Day (m3) |
1.533 |
1.035 |
|
Per Hour (m3) |
0.06 |
0.04 |
We test our ETP water from third party testing lab (Bureau Veritas) after every 6 months. Our ETP third party test result is very good. Our last test result is given below.
Testing Lab : Bureau Veritas
Date Received : November 14.2017
Report Date : November 26.2017
Test Parameter |
Result | Unit |
Test Method |
pH Value |
7.4 at 230C | – |
APHA 4500-H+ B:2012 & U.S. EPA 150.2 |
Total Suspended Solids (TSS) |
7 | mg/L | APHA 2540 D:2012 |
Chemical Oxygen Demand (COD) | 76 | mg/L |
APHA 5220 B:2012 & U.S EPA 410.3 |
Biochemical Oxygen Demand (BOD5) | 26 | mg/L |
APHA 5210 B:2012 |